2015
Permanent URI for this collection
Browse
Browsing 2015 by Author "Mohan, B S"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Comparing To Estimate The Use Of Alternative Energy Over Grid Energy(2015-06-26T05:45:29Z) Mohan, B S; Prabha, G; Mahesh, KThe objective of this paper is to see the energy potential .i.e. either Electrical or Thermal energy at Acharya campus using Biodegradable waste,Solar energy and wind energy at campus space. The Biodegradable waste that can be collected through various sources like, Kamakshi canteen, Sri Durga Mess, HKG hostel Kitchen, Upcoming food court, Dry leaves, Lawn - Plantation andAnimal dung. The total biodegradable waste would be calculated on the number of working day at campus. The Solar potential at campus is calculated on the installing capacity over constructed (Building) roof-tops and area available for further expansion. Based on 220W panel dimensions we are calculating the total solar energy potential for available area. Considering 9hours of isolation at campus and 80% of energy conversion capability we can estimate the total energy potential from sun at campus. The wind potential at campus is calculated on the installing capacity over the edge of the constructed building roof-tops and area available for further expansion. Based on 1 kW wind generator we are calculating the total wind energy potential for available area. Considering 20 hours of isolation at campus and 300 days of operation and 40% of energy conversion capability we can estimate the total energy potential form wind at campus. The energy potential from bio-gas plat and solar energy and wind energy would give us the total energy potential estimated at campus for consumption. Load dynamics at campus varies from 9am to 5pm during regular working days. There is a need to calculate the demand for energy during each month and the energy generated is distributed in an efficient mannerItem Reviewing Voltage Profile , Power & Reactive power compensation in EHV AC & UHVAC line at Power & Fractional Frequency(2015-03-16T09:38:41Z) Mohan, B S; Mahesh, K; Santhosh, SThis paper analysis the voltage profile Power transfer capacity, active & reactive power flow in line at 50Hz and 50/3Hz. It‟s known that higher the transmiss ion voltagelower are the voltage losses and degree of compensation [1]. In this paper, 765kV and 1200kV levels are taken as transmission voltages for a line length of 1200Km. For each transmission voltage load is varied from 0% to 150% of surge impedance load to measure foresaid parameters. While studying the parameters at fractional frequency transmission system (ffts), loads are connected to 50Hz system through step - up cycloconverter