The present study involves the Comparison, Modeling and Analysis of Ducting for the Air- Conditioning system used on the Schilka Weapon Control System. The upgrading of the Air-conditioning unit is to improve the habitable environment for the crew. The optimum temperature for the crew to work while using the Nuclear Biological Chemical (NBC) warfare protection suit is not more than 28 °C. The Air-conditioning system is based upon the spot cooling principle. The modeling is carried out on SOLID WORKS 2013 and post modeling Computational fluid dynamics analysis is done on the NX6 analysis software. The results obtained from the current system are taken as a base-line. Heat gain and Pressure drop are identified as problems and rectified using insulation and repositioning of distribution box and remodeling of the Air Conditioning unit’s Ducting.